Sanjaykumar Desai

Sanjaykumar Desai

Executive Trainee

Followers of Sanjaykumar Desai533 followers
location of Sanjaykumar DesaiJamnagar, Gujarat, India

Connect with Sanjaykumar Desai to Send Message

Connect

Connect with Sanjaykumar Desai to Send Message

Connect
  • Timeline

  • About me

    Power Plant manager- Reliance industries limited at Reliance Industries Limited , Jamnagar

  • Education

    • L.D College of Engineering - Ahmedabad

      2003 - 2007
      Bachelor of Engineering (B.E.) Electrical Engineering Technologies/Technicians Distinction
  • Experience

    • Torrent pharmaceuticals limited

      Jul 2007 - Jul 2008
      Executive Trainee

      Project executive trainee, Erection and commissioning of 66kV AIS substation and MV/LV switchgear with EDG network• Designing, erection & commissioning of LT and HT panel, captive power plant of 5.25 MW having D.G. sets and also synchronization panel of D.G and 66 KV substation, LT/HT motor selection & design of transformer and generating unit, design of lighting distribution system, design & erection PMCC MCC, PDB, LDB & PCC panel in flame proof and non-flame proof area and other type of electrical utility.• Handle responsibilities of supporting senior level engineers in controlling and supervising and auxiliary equipment in Electrical network of Process plants and main receiving substation• Play a lead role in areas of designing and testing Lighting and HVAC system • Identify and update plant electrical related operational and equipment issues to the project manager and senior power plant electrical engineer Show less

    • Reliance Industries Limited , Jamnagar

      Jul 2008 - Jan 2022
      Power Plant manager- Reliance industries limited

      I am a professional engineer diversely experienced in Projects, Engineering, Design, Commissioning, Testing, Reliability and Maintenance phases of Mission Critical facilities such as Oil and Gas, Petrochemicals, Power and Utilities complex. As an electrical engineer, I have always been passionate about learning new skills in the field of power systems and automation and use the expertise to solve the challenges associated with the system.My extensive involvement in the Erection, Testing, Commissioning activities of the power plant includes, • 2 numbers of 8DN9 type 220kV GIS switchgear (19 bays and 12 bays). • 2 bays of 220kV AIS. • 8 numbers of 8DA10 type 33kV GIS switchgear (Total 200 bays). • 11kV, 6.6 kV, 0.415kV switchboards. • Fast Bus Transfer scheme at 6.6kV level. • ACO at 6.6kV and 0.415kV with two and/or three sources. • 2x136MW Frame 9E Gas Turbines and Generators, and Ex2100e AVRs. • 1x90MW Steam Turbine and Generator, and AVR. • Energy Management System for Metering, Load Shedding, Disturbance recording. • Motors up to rating of 2.1MW on DOL. • Upstream ends of motors with rating of 11MW, 15MW, 30MW on VSD/Auto Transformer starters. • Transformers with a rating of 213MVA, 174MVA, 105MVA, 40MVA, 25MVA, 2.5MVA. • 220kV and 33kV cables commissioning and online/offline PD monitoring. • MCC, PCC, Battery Chargers, Inverters, and other BOP. Show less

    • Reliance Industries Limited

      Dec 2021 - now
      Section head EHV and ICCP Reliability
  • Licenses & Certifications