Muhammad Hashim

Muhammad hashim

bookmark on deepenrich
location of Muhammad HashimKarachi Division, Sindh, Pakistan
Followers of Muhammad Hashim3000 followers
  • Timeline

  • About me

    Maintenance Electrical Engineer At O&m 2*660MW Coal-Fired Thermal Power Plant PQPC Power China Gansu Energy & Investment company Port Qasim Karachi

  • Education

    • Quaid-e-awam university of engineering, sciences and technology nawabshah

      2011 - 2014
      Bachelor’s degree electrical engineering (power) a
  • Experience

    • Advance institute of technical engineering, science & technology, moro. sindh

      Feb 2015 - Dec 2015
      Principal engineer

      Advance Institute Of Technical Engineering, Science & Technology, (A.I.T.E.S.T) Moro is a technical college which is affiliated from Sindh Board Of Technical Education (SBTE) Karachi.It offers Diploma Of Associate Engineer (DAE 3years Degree) Program in following technologies.1. Civil2. Electrical3. Computer

    • China railways signal and communication crsc int. corp. beijing china

      Jan 2016 - Jul 2019
      Assistant engineer

      * Supervised Installation, Commissioning & Testing of all indoor and outdoor Electrical Equipment in the project premises. Like-wise: 3-Phase Power supply Panels, 30kva UPS battery backup, 30kva diesel generator, Earthling/Grounding for electrical equipment room, axel counter sensors, point machines (3phase motor), Indicators,detectors, Axel Insulated Rail-Joints IRJ, Magnetic Lock ML Key Box, Track circuit boxes (feeder & receiver), junction boxes for multiple cores signal and power cables, signal poles with concrete foundations etc.* Excavation of Trenches for lying Signal & Optical Fiber Cables in yard section as well as block section.* Yard Measurement and Marking according to Yard Design for installation of different outdoor equipment’s.* Continuity & Insulation resistance test for multiple cores of Signal Cable Drums.* Maintains Project Schedule by Monitoring Project Progress, Coordinating Activities & Resolving Problems.* Monitor Progress of Civil Contractors as per Scheduled agreed.* Monitoring the Performance of Workers, Sub-Contractor’s Site Activities.* Develop Complete Work at Site to Start the Site Activities Efficiently.* Cooperate and communicate effectively with project manager and other project participants to help and technical support.* Permit authorization, Issue acceptance for work to start and permit cancelation on completion of work.* Determines project schedule by studying project plan and specifications, calculating time requirements, sequencing project elements.* Interprets and implements quality assurance standards.* Maintaining all important documents including certificates, calibration reports, test result, inspection request and site inspection data.* Ensure compliance with company’s Health and Safety policy.* Control and monitoring all activities following Method of statement & Quality Management System Show less

    • Powerchina gansu energy investment company limited (pakistan branch)

      Aug 2019 - now
      O&m maintenance electrical engineer

      * Perform preventive maintenance, corrective maintenance & inspection of thermal power plant electrical equipment including 11kV distribution PC system, 440V distribution system, 500KV Relay protection system, induction motors, backup generators, local cabinets for secondary control circuits of sub-systems, MCCs, UPS, VFDs, Battery banks etc. On daily basis, carry-out Permit to Work (PTW) and routine-wise manage about electrical faults at MIS software. * Provide prompt response to inquiries whenever there is a breakdown, and resolve the issue as quickly as possible. * Ensure that equipment in good working order so as to prevent disruption of activities. Recommend replacement for old or faulty electrical components or fittings to the management. * Fault reporting and inspection of 500 kV Protection systems (Alstom, Siemens).Installation, Charging Test & Discharging Test of Battery Ranks GF-2500A (2V2500Ah/10HR 25C), GF-600A (2V600Ah/10HR 25C) & GF-600A (2V100Ah/10HR 25C).Troubleshooting of JZE DC and Battery system for power and control purposes.* Testing and Inspection of 11kV Vacuum Circuit Breakers.* 11kV asynchronous motor high voltage tests: IR and winding resistance, AC withstand test and DC withstand test. * Study and revise plant electrical drawings including SLD, actual cabinet wiring diagrams, relay logics, interlocking, and layout drawings.Familiar about testing of generator protections NARI PCS-985G Generator Relay.* Familiar about testing of transformer protections NARI PCS-985G Transformer Relay.Ensuring and maintaining of Load Balancing of Distribution Network.* Supervised Erection and Commissioning of five Conveyor belts and 3 Transfer Station along with different switches such as: Deviation Switch, Pull Chord Switch, Material flow switch etc.* Tripping Analysis and Localization of Faults in Minimum time.* Occupational Health and Safety management including JHA sheet in work permits, First Aid, Rescue methods. Show less

  • Licenses & Certifications

    • Certificates of acheivements