Md Saheed Akhtar, CMRP®

Md saheed akhtar, cmrp®

bookmark on deepenrich
location of Md Saheed Akhtar, CMRP®Jajpur, Odisha, India
Followers of Md Saheed Akhtar, CMRP®312 followers
  • Timeline

  • About me

    Manager O&M Reliability, Electrical|Project Manager|Commissioning|Design Engineer

  • Education

    • Aissce

      2005 - 2007
      10+2 physics, chemistry and maths

      Secured 90%(approx) marks

    • Dav centenary public school baniahir

      2004 - 2005
      10th science, maths and english

      secured 90%(approx.) marks

    • Biju patnaik university of technology, odisha

      2007 - 2011
      Bachelor’s degree electrical engineering 1st

      Technically sound in Electrical machines, Power Transmission and distribution.

  • Experience

    • Adani power

      Aug 2011 - Oct 2014
      Power plant manager

      ADANI(5*660 MW power plant)1. Successful commission of AVR,GRP(generator protection),GT & UT Protection & relay Testing and its protection function.2. Commissioning of 33KV,11KV,6.6KV and 415V switchboard and its auto and synchronising logic through DCS.3. Commissioning of Battery Charger,Battery Bank and Elevator System.4. Commissioning of BUS TRANSFER SYSTEM(BTS).5. Commissioning of EMERGENCY DG SYSTEM.6. Maintenance of HT & LT breaker,HT & LT motor.7. Mentoring subordinates and ensures amicable employee relations across the Plant.8. Co-ordination with client in As-Built drawing submission, test report submission etc.9. Responsible for Fast Trouble shooting/Fault Analysis of all Electrical control and protection circuits during faulty conditions and submission of fault analysis report to the HOD.10. Responsible for preparation of proper documentation and record of all the maintenance & breakdown activities up to handing over of the system. Show less

    • Alfanar

      Oct 2014 - Sept 2019
      Testing and commissioning engineer

      Skilled in END TO END TEST between substation and successful energization of line and hence substation. Expertise in ABB 380 KV (one and half circuit breaker) and switchgear scheme.Expertise in SIEMENS 380 kv (one and half circuit breaker), Hyundai 132/110 kv(two bus single line) scheme.Expertise in substation testing e.g.: CT, VT and BRAEKER TIMING for 380 kv, 132 kv, 110 kv, 33kv , 13.8 kv.Skilled in primary injection in GIS for bus bar stability and transformer stability.

    • Tata steel

      Sept 2019 - now
      Manager
  • Licenses & Certifications

    • Cmrp certified

      United latino students association
      Sept 2023
      View certificate certificate
    • Certified maintenance and reliability professional (cmrp)

      Smrp
      Sept 2023
    • Etap

      Power projects
    • Certified maintenance and reliability professional (cmrp)

      Smrp
      Sept 2023
  • Volunteer Experience

    • Protection Engineer in substations(8922.8824,8804)

      Issued by ABB on Nov 2015
      ABBAssociated with Md Saheed Akhtar, CMRP®